CMW Models
[Specifications]
Model | Size | Dynamic friction torque Td [N・m] | Static friction torque Ts[N・m] | Coil(at20℃) | Heat resistance class | Rotating part moment of inertia [kg・m2] | Total work performed until readjustment of the air gap ET[J] | Armature pull-in time ta[s] | Torque build-up time tp[s] | Torque decaying time td[s] | |||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage [V] | Wattage [W] | Current [A] | Resistance [Ω] | ||||||||||
CMW-06N-H□H | 06 | 5 | 5.5 | DC24 | 11 | 0.46 | 52 | B | 1.66×10-4 | 36×106 | C:0.020 / B:0.015 | C:0.041 / B:0.033 | C:0.020 / B:0.015 |
CMW-08N-H□H | 08 | 10 | 11 | DC24 | 15 | 0.63 | 38 | B | 4.78×10-4 | 60×106 | C:0.023 / B:0.016 | C:0.051 / B:0.042 | C:0.030 / B:0.025 |
CMW-10N-H□H | 10 | 20 | 22 | DC24 | 20 | 0.83 | 29 | B | 1.71×10-3 | 130×106 | C:0.025 / B:0.018 | C:0.063 / B:0.056 | C:0.050 / B:0.030 |
CMW-12N-H□H | 12 | 40 | 45 | DC24 | 25 | 1.04 | 23 | B | 4.53×10-3 | 250×106 | C:0.040 / B:0.027 | C:0.115 / B:0.090 | C:0.065 / B:0.050 |
※Kinetic friction torque Td values calculated at relative velocity of 100min-1 min.Depending on the initial torque characteristics, break-in to condition the engaging surfaces may also be required.
Model | Size | Motor output[kW]3-phase 4P | Speed Reducers | Mass[kg] | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Model | Rated output shaft | Speed reduction ratio 1/□ | Oil volume[L] | |||||||||
10 | 20 | 30 | 40 | 50 | 60 | |||||||
CMW-06N-H□H | 06 | 0.2 | N-2SA | Torque[N・m] | 78.2 | 79.9 | 85.3 | 78.6 | 88.9 | 76.1 | 0.5 | 16 |
O.H.L.[N] | 1770 | 2280 | 2620 | 2930 | 3160 | 3230 | ||||||
CMW-08N-H□H | 08 | 0.4 | N-2A | Torque[N・m] | 79.8 | 102 | 86.9 | 104 | 98.5 | 100 | 0.5 | 32 |
O.H.L.[N] | 1760 | 2240 | 2630 | 2880 | 3140 | 3230 | ||||||
CMW-10N-H□H | 10 | 0.75 | N-3A | Torque[N・m] | 165 | 180 | 180 | 188 | 187 | 164 | 1.0 | 44 |
O.H.L.[N] | 2250 | 2900 | 3370 | 3720 | 4040 | 4370 | ||||||
CMW-12N-H□H | 12 | 1.5 | N-4A | Torque[N・m] | 292 | 293 | 301 | 302 | - | - | 2.0 | 72 |
O.H.L.[N] | 2780 | 3640 | 4210 | 4680 |
※The induction motors are fully sealed external fan motors that conform to the JIS C4210 standard (for 0.2 kW and 0.4 kW models) or the JIS C 4213 standard (for 0.75 kW models or higher).
※The power supplies for the motors are 3-phase, 200 V AC at 50 Hz, or 200/220 V AC at 60 Hz.
※If you desire a special voltage (5 Power Supply Specifications), different number of poles, or the like for the induction motor, contact Miki Pulley.
※Speed reducer is made by Hirai Reduction Gear Manufacturing Co.
[Dimensions]
Model | Dimensions of part | Dimensions of shaft | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A1 | A2 | B1 | B2 | C1 | C2 | D1 | D2 | E | F | G | H | J | K | KL | L | M | N | Z | Q | S | U | W | |
CMW-06N-H□H | 105 | 105 | 132 | 157 | 75 | 135 | 160 | 130 | 110 | 86 | 15 | 215 | 375 | 117 | - | 492 | 205 | 170 | 12 | 50 | 25 | 28 | 8 |
CMW-08N-H□H | 115 | 112 | 140 | 165 | 82 | 146 | 160 | 145 | 110 | 100 | 15 | 226 | 412 | 135 | 124 | 547 | 225 | 187 | 11 | 50 | 25 | 28 | 8 |
CMW-10N-H□H | 125 | 146 | 155 | 200 | 102 | 184 | 200 | 163 | 120 | 125 | 16 | 284 | 477 | 159 | 131 | 624 | 255 | 222 | 12 | 65 | 30 | 33 | 8 |